Prediction Method on Fire Endurance of Post Installed Rebar Beams

LU Zhoudao, SU Shiya, YU Jiangtao

Abstract

  For quantitative evaluation of fire endurance, this paper presented a prediction method on the fire endurance of post installed rebar beams exposed to elevated temperature. It was based on equivalent section method, which regarded initial sections as ladder sections by strength reduction of concrete and reinforcement under high temperature. The simplified calculation theory about the mechanical properties of members at ambient temperature and the calculation formula of the ultimate strength of single anchored rebar in fire were used. The feasibility of the theoretical calculation was evaluated through a comparison between the results obtained by the prediction method and the experimental measurements. The results showed that the fire endurance calculated by formula agreed well with the test data with the error of 15%, equivalent to about 15 mins. It was feasible to use this method to predict the fire endurance.

 

Keywords: fire endurance,  bonded rebar,  high temperature,  equivalent section method


Full Text:

PDF


References


XIONG X Y, XU L X. HU J Z. Pull-out experiment study of chemically bonded rebar [J]. Architecture Technology. 2001. 31(6); 383 - 384. (In Chinese)

XIE Q. Experimental study on behavior of bonded-in reinforcement anchorage group I)]. Shanghai; College of Civil Engineering. Tongji University, 2006:38 - 50. (In Chinese)

SI W J, ZHOU X D, HUANG J Z. etal. Experimental study on post-embedding technology with epoxy mortar as bonding agent[j]. Building Structure. 2001 , 31(3): 9- 12. (In Chinese)

YAN F, ZHANG H Y, WANG Z, et al. Experimental research on the behavior of RC columns with post-installed chemically bonded longitudinal rebars under reciprocating load [j]. Building Structure,2003, 33 ( 10): 37 - 39. (In Chinese)

ZHANG J R. WU J. YANG J H, et al. Experimental research on the behavior of concrete beams with adhesive reinforcement under static and fatigue bending loads [J]. Journal of Building Structure, 2005, 26(5) :38 - 45. (In Chinese)

EN 1992-1-2:2004 Eurocode 2: Design of concrete structures. Part 1-2: general rules-structural fire design [S_. Brussels: European Committee for Standardization,2004:30-34.

EN 1993-1-2:2005 Eurocode 3: Design of steel structures. Part 1-2; general rules-structural fire design[S . Brussels; European Committee for Standardization,2005:27 - 44.

FISHER. Technical Handbook-Asia [J]. 4th ed. Waldachtal; Fisher Group of Companies,2008: 10- 15.

KUNZ J. Fire design; state of the art [R]. Shanghai; Hilti Corporation, 2006; 11 - 16.

ZHENG W Z. HOU X M, WANG Y. Progress and prospect of resistance of reinforced concrete and prestressed concrete structures[J]. - Journal of Harbin Institute of Technology. 2016,48( 12): 1 - 18. (In Chinese)

HOU X M. ZHENG W Z. Experiment on and analysis of the mechanical performance of unbonded prestressed concrete continuous slab after elevated temperature [J]J. Journal of Hunan University (Natural Sciences). 2010, 37 ( 2) : 6 - 13. (In Chinese)

YUAN G L, LIU T, YAN Y H. Experimental study of behaviors of RC structures exterior joints with post-embedded bars under cyclic loading after treatment at high temperature [J]. Journal of China University of Mining & Technology. 2008. 37(1); 19 -23. (In Chinese)


Refbacks