Evaluation of nitrogen treatment in the wastewater treatment plant by dynamic optimization

Dinh Huan Nguyen, M.A. Latifi

Abstract

This article studies the efficiency of wastewater treatment by two different methods of biological treatment based on two plants. The Benchmark wastewater treatment plant (WWTP) has two first anoxic tanks for organic treatment and denitrification; next three aerobic tanks are used for organic and nitrification treatment; nitrates from the last aerobic tank are circulated to the first anoxic tank to continue the denitrification. The Verulam WWTP is comprised of an anoxic tank for treating organic material, the next two aerobic tanks for nitrification, the fourth anoxic tank for denitrification and, finally, the aerobic one for organic matter settling. Thus, both WWTPs have two anoxic tanks and three aerobic tanks but the arrangement of tanks is different. While considering the cost of the aeration system, our research results indicate that the Benchmark WWTP is about 15% more effective compared to the Verulam one. Besides, the Benchmark WWTP is easy to control the effluent by internal recycling.

 

 

Keywords: Benchmark WWTP, Verulam WWTP, wastewater treatment, methods of denitrification, optimization.


Full Text:

PDF


References


HENZE M., GRADY Jr C. P. L.., GUJER W. et al. Activated Sludge Model No. 1. Technical Report 1, IAWQ, London, 1987.

HENZE M., GUJER W., MINO T. et al. The Activated Sludge Model No. 2: Biological phosphorus removal. IAWQ Scientific and Technical Report No. 3, Water Science and Technology, 1995, 31(2): 1-11. https://doi.org/10.1016/0273-1223(95)00175-M

GUJER W., HENZE M., MINO T. & VAN LOOSDRECHT M.C.M., Activated sludge model No.3. Water Science and Technology, 1999, 39(1): 183-193. https://doi.org/10.1016/S0273-1223(98)00785-9

GUJER W., HENZE M., MINO T. et al., Activated Sludge Model No. 2D, ASM2D. Water Science and Technology, 1999, 39(1), 165-182. https://doi.org/10.1016/S0273-1223(98)00829-4

ALEX J., BENEDETTI L., COPP J. et al. Benchmark Simulation Model no. 1 (BSM1). IWA Taskgroup on Bechmarking of Control Strategies for WWTPs, 2008. https://www.iea.lth.se/publications/Reports/LTH-IEA-7229.pdf

HREIZ R., LATIFI M.A, & ROCHE N. Optimal design and operation of activated sludge processes: State-of-the-art. Chemical Engineering Journal, Elsevier, 2015, 281: 900-920. https://doi.org/10.1016/j.cej.2015.06.125

DREWNOWSKI J., ZABOROWSKA E., and HERNANDEZ DE VEGA C. Computer Simulation in Predicting Biochemical Processes and Energy Balance at WWTPs. Water, Wastewater and Energy in Smart Cities. E3S Web of Conferences 30, Article ID 03007: 1-12, 2018. https://doi.org/10.1051/e3sconf/20183003007

ISSA H.M. Optimization of Wastewater Treatment Plant Design Using Process Dynamic Simulation: a Case Study from Kurdistan, Iraq, 2019. ARO-The Scientific Journal of Koya University, 7(1), pp. 59-66. https://doi.org/10.14500/aro.10488

MUOIO R., PALLI L., DUCCI I., COPPINI E., et al. Optimization of a large industrial wastewater treatment plant using a modeling approach: A case study. Journal of Environmental Management, 2019, 249, Article ID 109436. https://doi.org/10.1016/j.jenvman.2019.109436

BORZOOEI S., AMERLINCK Y., PANEPINTO D. et al. Energy optimization of a wastewater treatment plant based on energy audit data: small investment with high return. Environmental Science and Pollution Research, 2020, 27: 17972–17985. https://doi.org/10.1007/s11356-020-08277-3

NGUYEN D.H., LE P.C., & LATIFI M.A. Wastewater Treatment Plant Optimization: Case Study of Benchmark Plant. In: JEON H.Y. (ed.) Sustainable Development of Water and Environment. ICSDWE 2020. Environmental Science and Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-45263-6_11

NGUYEN D.H., & LATIFI M.A. (2020) Simulation and Optimization of Hoa Cam Wastewater Treatment Plant. In: JEON H.Y. (ed.) Sustainable Development of Water and Environment. ICSDWE 2020. Environmental Science and Engineering. Springer, Cham. https://doi.org/10.1007/978-3-030-45263-6_20

COPP J.B. The COST Simulation Benchmark: Description and Simulator Manual. COST Action 624 and COST Action 682, 2001.

Modelling & Integrated Assessment. http://iwa-mia.org/benchmarking/

Verulam, South Africa. https://www.organicawater.com/case-study/verulam-south-africa/

FARAI T.M. Modelling municipal wastewater treatment plants for industrial effluent discharge. PhD thesis, University of KwaZulu-Natal, 2016.

PSE. gProms, Process Systems Enterprise, 1997–2009, www.psenterprise.com.

NGUYEN D.H, LATIFI M.A, LESAGE F. and MULHOLLAND M. Dynamic simulation and optimization of wastewater treatment plants. Proceedings of the International Conference on Process Control (PC), Strbske Pleso, 2013, pp. 407-414. https://doi.org/10.1109/PC.2013.6581445.

CUTHRELL J.E. and BIEGLER L.T. On the Optimization of Differential-Algebraic Process Systems. AIChE Journal, 1987, 33(8), 1257-1270. https://doi.org/10.1002/aic.690330804