Experimental Study and Bond Slip Analysis on Mechanical Properties of Half Grout Sleeve Splicing of Rebars after High Temperature
Abstract
In order to avoid failure of the half grout sleeve splice of rebars in prefabricated concrete structures after fire and serious consequences,27 14 mm-half grout sleeve splicing specimens of rebars were manufactured to study their mechanical properties by unidirectional static tensile test after high temperature. The test results showed two failure modes of the specimens after high temperatures including fracture and pull-out of rebars, in which the latter one was more likely to occur when the specimens were cooled by water. During the tensile process, the relative slip can occur between the sleeve and the rebar connected at the grouting side, and the slip increased nonlinearly with the increase of the temperature. Based on the test results after 600 ℃ high temperature and the existing bond strength formulas,suggestions were given to avoid the pull-out failure of rebars after high temperature. According to approximate analysis of steel slip in elastic stage,the quadratic function curve between the slip and temperature under natural cooling after high temperature was obtained.
Keywords: half grout sleeve splicing, unidirectional static tension test, after high temperature, failure mode
Full Text:
PDFReferences
EINEA A, YAMANE T, TADROS M K. Grout -filled pipe splices for precast concrete construction [J]. Pci Journal, 1995, 40(1):82—93.
KIM Y. A study of pipe splice sleeves for use in precast beamn - column connections [D] . Austin: Ferguson Structural Engineering Laboratory, University of Texas at Austin, 2000: 21—55.
ZHAO X L, GRUNDY P, LEE Y T. Grout sleeve connections under large deformation cyclic loading [C] //The Twelfth International Offshore and Polar Engineering Conference. International Society of Offshore and Polar Engineers, 2002: 53—59.
ZHAO X L, GHOJEL J, GRUNDY P. Behaviour of grouted sleeve connections at elevated temperatures[J]. Thin-Walled Structures, 2006, 44 (7): 751—758.
GOH H M. Parametric study of steel grouted splice sleeve with in tegrated double springs under axial tension [D]. Johore Johor Bahrn: Universiti Teknologi Malaysia, 2009: 1—68.
KIM H K. Bond strength of mortar-filled steel pipe splices reflecting confining effect [J]. Journal of Asian Architecture and Building Engineering, 2012, 11 (1): 125—132.
SAYADI A A, RAHMAN A B A, JUMAAT M Z B, et al. The relationship between interlocking mechanism and bond strength in elastic and inelastic segment of splice sleeve [J]. Construction and Building Materials, 2014, 55: 227—237.
SAYADI A A, RAHMAN A B A, SAYADI A, et al. Effective of elastic and inelastic zone on behavior of glass fiber reinforced poly mer splice sleeve [J]. Construction and Building Materials, 2015, 80: 38—47.
HENIN E, MORCOUS G. Non -proprietary bar splice sleeve for precast concrete construction [J]. Engineering Structures, 2015, 83: 154—162.
AMELI M J, BROWN D N, PARKS J E, et al. Seismic column-to-footing connections using grouted splice sleeves [J]. ACI Structural Journal, 2016, 113 (5): 1021—1030.
ZHENG Y F, GUO Z X. Structural performance of innovative grout
sleeve splicing for rebars under cyclic loading [J]. Journal of Hunan University (Natural Sciences), 2016, 43 (11) :136—145.(In Chinese)
YUAN H, ZHENGGENG Z, NAITO C J, et al. Tensile behavior of half grouted sleeve connections: Experimental study and analytical modeling [J]. Construction and Building Materials, 2017, 152: 96—104.
Refbacks
- There are currently no refbacks.