Experimental Study on the Performance of Prestressed Force and Outsourcing Cement Filling Material Strengthening Large Span RC Space Truss

BU Liang-tao, LIU Shang-kai, LIU Chan-juan, WU Kan-quan

Abstract

Based on the engineering background of an island water diversion aqueducts truss, this paper put forward a method using prestressed force and outsourcing cement filling material to strengthen the bottom chord of reinforced concrete truss, used the hierarchical load test method to carry out in-situ static load experiment on the strengthened truss, tests deflection, strain(stress) value and their changes of the main control section of truss at different levels of loads, made a comparative analysis of the test results, calculated the value of finite element method, and obtained the mechanical performance of the truss after reinforcement. The experimental results show that the use of prestressed force and outsourcing cement filling material to strengthen truss can improve the bearing capacity of truss structures to a great extent, and new structural layers can work with the original structural layers and their deformation coordination is good. The reinforcement effect is also ideal.

 

 

Keywords: truss structure,  prestressed force,  reinforcement,  static load test


Full Text:

PDF


References


QIAO Dun. The technology of external prestressed tendons and its application in bridge engineering [J]. Journal of Chongqing Jiaotong University. 1992. 11 (3) : 46 — 55. (In Chinese)

AI Jun. SHI Li-yuan. Discussion of design and construction method on extraneous prestressed strengthening technique for bridge [J]. Journal of Southeast University: Natural Sciences. 2002. 32 (5). 771-774. (In Chinese)

ZHU Dian-wen. TANG Xiao-bing. ZHANG Wan-ping. The concrete bridge with external presstressing [J]. Thansportation Science & Technology. 2002(6) :38_ 41. (In Chinese)

LI Xing-sheng. WANG Gang. GUO Ying. Research of strengthening techniques for long span prestressed concrete truss bridges [J]. Bridge of the World. 2010 (4): 68 — 70. ( In Chinese)

GB 50367 — 2013 Design code for strengthening concrete structure [S]. Beijing. China Architecture &- Building Press,2013: 35 — 36. (In Chinese)

JGJ/T 279 — 2012 Technical specification for strengthening building structures with external prestressing tendons [S]. Beijing: China Architecture &- Building Press.2012:8— 10. (In Chinese)

BU Liang-tao. YE Zhen. ZHOU Zi-fan. et al. Experimental study on КС beam reinforced by reinforcing steel bar mesh mortar subject to secondary load[J]. Journal of Building Structures.2006.27(5) :94 100. (In Chinese)

Liang-tao. YE Zhen. HU Shang-yu. Experimental study of КС beam strengthened by ferrocement mortar subject to secondary load [J]. Journal of Hunan University: Natural Sciences.2007.34(3) : 15— 19. (In Chinese)

BU Liang-tao. CHEN Jun. LU Chen. Experiment on fullscale RС beam reinforced by polyvinyl alcohol-engineered cementitious composite mortar in flexture subjected to secondary load [J]. Journal of Hunan University: Natural Sciences. 2011, 38(1) :1-7. (In Chinese)

GB/T 50784 — 2013 Technical standard for in-site inspection of concrete structure [S]. Beijing: China Architecture &- Building Press.2013:61— 64. (In Chinese)

GB/T 50152 — 2012 Standard methods for testing of concrete structure[S]. Beijing: China Architecture &- Building Press. 2012:14 — 20. (In Chinese)

PENG Da-weng. DING Wen-sheng. The research of static loading test on large-size steel tube truss structured [J]. Journal of Shanghai Institute of Technology: Natural Science.2010.10 (3): 180 — 185. (In Chinese)