Research on Water Tightness of Standing Seam Roof System under Large Deformation

LUO Xiaoqun,ZHANG Jindong,YANG Bin

Abstract

In order to study whether the standing seam roof system installed on a flexible roof structure has the ability to adapt to the large deformation of the flexible roof structure and whether panel details of the roofing system can ensure the water tightness under large deformation, taking the roof structure of the swimming stadium in Suzhou Industrial Park Sports Center as an example, a 6.6m×6.6m test unit was used to design the full-scale water tightness test of the metal roofing system under large deformation. Through numerical analysis, stress and deformation distribution of the roofing system was explored under large deformations in the flexible roof structure. A refined finite element model was also established to evaluate the water tightness of key details in the standing seam roof panels. The test and analysis verified that the standing seam roof system had the ability to adapt to the large deformation of the flexible roof structure, the calculated angle between standing seams was only 2.18°,and water tightness can be ensured at the same time.

 

 

Keywords: water tightness,  standing seam panel,  large deformation,  numerical analysis


Full Text:

PDF


References


ZHANG Y,LIU Y B,LIU D P. Metal roofs and standing seam roof system[J] .China Building Waterproofing,2010(23):1—7.(In Chinese)

CHENG M,SHI Y J,WANG Y Q,et al. Experimental study on loading properties of the roofing system of National Showplace[J] . Building Structure,2005,35(2):3—5.(In Chinese)

DONG Z,ZHANG Q L,SHI J. Experiment study and design analysis of Al-Mg-Mn alloy roof pane[l J] . Building Structure,2008,38(3):69—72.(In Chinese)

WANG D Z,LI W L,ZHI X D. Static stability analysis of reticulated shell with purlin roofing system [J] . Engineering Mechanics, 2017,34(S1):71—77.(In Chinese)

ZHI X D,ZHANG T,LI W L,et al. Effect of roof system on elastoplastic stability and seismic performance of single-layer reticulated shells [J] . China Civil Engineering Journal,2017,50(2):19—26.(In Chinese)

JING X K,LI Y Q. Effective static wind load for clips of standing seam roof system [J] . Journal of Tongji University (Natural Science),2013,41(11):1630—1635.(In Chinese)

LUO Y F,ZHENG X J,GUO X N,et al. Loading behavior analysis of an aluminum alloy roof structure system under wind loads[J] . Journal of Chongqing University,2013,36 (10):94—100(. In Chinese)

SONG X G,ZHANG Q L,LIU S R. Stability analysis and design proposals for cold-formed purloins under wind uplif[t J] .Journal of Hunan University (Natural Sciences),2010,37 (8):17—23.(In Chinese)

EL DAMATTY A A,RAHMAN M,RAGHEB O. Component testing and finite element modeling of standing seam roofs [J] . Thin- Walled Structures,2003,41(11):1053—1072.

ALI H M,SENSENY P E. Models for standing seam roofs[J] .Journal of Wind Engineering and Industrial Aerodynamics,2003,91(12/15):1689—1702.

SONG X,ZHANG Y,ZHANG Q. Failure modes and loading bearing capacity of corrugated steel roofs connected by standing seam clips [J] . International Journal of Steel Structures,2017,17(4): 1341—1352.

ARNOLD R,BANISTER C,WEIR A,et al. Delivering London 2012: The velodrome[J] .Proceedings of the Institution of Civil Engineers: Civil Engineering,2011,164(6):51—58.


Refbacks

  • There are currently no refbacks.