Research on Method to Optimize Accuracy of γ- ray Backscatter Ash Analyzer

CHENG Dong, TANG Xiangdong, LI Fuhai, DAI Yang

Abstract

Measurement accuracy of γ-ray backscatter ash analyzer is greatly affected by the changes in the composition of the coal ash. In current ash analyzer, calibration is underway anew when measurement error is comparatively large, with a narrow measurement range, low accuracy and complicated operation. In this paper, the impact of changes in the composition of the ash on the accuracy of ash analyzer was analyzed from the working principle of γ-ray backscatter ash analyzer. A calibration model based on the dual low energy γ ray measurement was established,which can improve the measurement accuracy and can be achieved automatically on software. The calibration model was then used on a γ-ray backscatter ash analyzer, and the test results show that the existing deficiencies are overcome with an measurement error of less than 1%,meeting the required measurement accuracy of EJ/T1078-1998 γ- ray coal ash analyzer.

 

 

Keywords:  γ- rays,  ash detection,  coal quality


Full Text:

PDF


References


CHEN W L, XIONG Y H. Analysis of portable quick ash analyser [J]. Thermal Power Generation, 2007 (4):88—90 (In Chinese)

MA Y H, BENG F, XIAO D Y,et al. The effect of composition on the double–energy μ–ray penetration method [J]. Nuclear Electronics and Detection Technology, 1989, 9 (6):324—329 (In Chinese)

ZHANG Z K, YANG G X,LEI Z Y, et al. On–line determination of ask content of coal based on the transmission of bi–energy y-rays [J]. Nuclear Electronics and Detection Technology, 1991, 11 (3): 1S2—1S8 (In Chinese)

GAI L. Discussion on the method of improving the accuracy of coal ask measurement [J]. East China Science and Technology (Academias Edition), 2015 (3):355—355. (In Chinese)

CHEN B L. Development of portable fast measuring instrument based on low energy gammaray method [D]. Wuhan:Huazhong University of Science and Technology, 2007 (In Chinese)

ZENG Q D. y - ray coal ash detection sensor [J]. Electrical Measurement and Instrumentation, 1985(11):41—43 (In Chinese)

JU J Y. Based on the virtual instrument technology of the ask top PC software development [D]. Beijing: Department of Engineering Physics, Tcinghua University, 2012.(In Chinese)

DONG Y M. Application of low energy y–rayash measuring instrument in coal ask measurement [J]. Coal Preparation Technology, 1988(3):23—25 (In Chinese)

GU B H. Effect of average intensity method on reading of double energy gamma ray ask meter [J]. Journal of Coal Science, 2001, 26 (2):220—224.(In Chinese)

HUANG X B,BANG G R,SUN P N, et al. Low – energy y – ray backscattering method for measuring coal ask[J].Nuclear Technology, 2005, 28 (11):72—75. (In Chinese)

QIAN Y. Application of low energy y – ray coalash analyzer[J]. Coal Tesknology, 2011(6):43–45. (In Chinese)

NOGUCHI M, KAKIMOTO S, KAJIGAESHI S. 1,3–dipolar addition of nitrile oxides to 3a,4–dihydro–1–isoindolinones [R].Yamaguski University, 1987:43—49.


Refbacks

  • There are currently no refbacks.